Chiller

GCP-S|GCP-S Propane

The GCP-S is a chiller with an integrated tank designed to reliably maintain the temperature of your application.

 

Efficient & reliable

  • Power range from 8 to 200 kW for precise cooling with water or a water-glycol mixture.

Compact & modular

  • Space-saving design with a flexible platform concept for various applications.
  • In more than 20 market segments, including machine tools, lasers, filtration, recycling, additive manufacturing, and process cooling
  • Modern communication interfaces: Easy analysis and transmission of process data (integrated Modbus TCP / optional gateway for supporting a wide range of protocols, e.g., Profinet, Profibus, etc.)
     

Future-proof

  • Uses low GWP refrigerant R513A
  • Future-proof in the long term with a natural refrigerant Propane (R290) with an extremely low GWP (~3) – compliant with regulations in the long term.

Can be used worldwide

  • Standard equipment for common mains voltages (R513A: 400V/50Hz & 460V/60Hz | R290: 400V/50Hz).

Energy efficient

  • Meets relevant EU efficiency guidelines for low operating costs over the entire service life.

Precise temperature control

  • Temperature stability of ±1K (optional ±0.5K), coolant outlet temperature from -5°C to 30°C.

Modern communication interfaces

  • Easy analysis and transmission of process data (integrated Modbus TCP / optional gateway for supporting a wide range of protocols, e.g., Profinet, Profibus, etc.)

GCP-S Chiller –
Efficiency meets future-proofing

The GCP-S chiller offer maximum performance and reliability for industrial applications. With a power range of 8 to 200 kW and application with water or water-glycol mixtures, it guarantees precise and sustainable cooling for demanding processes.

Do you require higher cooling capacities (> 200 kW)? HYFRA offers customized solutions on request.

Future-proof thanks to the low-GWP refrigerant R513A

The series was specifically developed for the global market and uses the "low GWP" refrigerant R513A. It already meets all future legal requirements:

  • EU*: GWP limit of 750 from 2027
  • USA: GWP limit of 700 from 2026
  • Due to the very low refrigerant filling quantity, the CO2 equivalent value is below the relevant limits, so an annual leak test in accordance with the F-Gas Regulation is generally not required.
  • Air freight (non-hazardous goods) up to 12 kg. Simple setup with no additional security requirements.

*Cooling capacity > 12 kW: GWP limit of 750 / effective 2027

 

Future-proof in the long term with the natural refrigerant propane (R290) 

  • Extremely low GWP value (~3), ensuring long-term regulatory compliance. 
  • Safety built into the system. For propane, we provide practical recommendations for the safe and code-compliant installation of the unit.
  • Propane’s excellent thermodynamic properties enable maximum energy efficiency.
  • Propane not only offers high energy efficiency but also stable and, in the future, lower costs for refrigerant and maintenance - ensuring consistently low operating costs.

 

 

Global applicability & maximum energy efficiency

The GCP-S is already designed for the common mains voltages of (R513A: 400V/50Hz & 460V/60Hz | R290: 400V/50Hz). All models meet the strict energy efficiency standards (EU) 2015/1095 and (EU) 2016/2281, thus achieving significant operating cost savings throughout the entire product life cycle.

 

Compact design

The appliance dimensions have been optimised so that little space is required for installation despite the high cooling capacity.
 

Precise temperature control & smart sensors

The cooling performance remains constant under all conditions:

  • Temperature stability as standard: ±1K (option: ±0.5K).
  • Temperature range: Coolant outlet temperature -5°C to 30°C, ambient temperature -20°C to 55°C.

In addition, an extensive sensor technology is installed that monitors important operating parameters, including supply temperature, supply pressure, and tank level. Enables predictive maintenance, making it easier to plan maintenance intervals and reducing unplanned downtime.

 

User-friendly 

Intuitive display with text-based interface for easy operation.
 

Efficient cooling for industrial precision

How does a cooling water chiller work?

This chiller operates in a closed loop and ensures that the process is maintained at a constant temperature. The medium is cooled to the defined setpoint temperature within the unit and fed to the consumer via a pump. There, it absorbs the process heat generated and is then returned to the chiller, where the heat is dissipated. This continuous control loop minimizes temperature fluctuations and ensures high process stability.

 

Versatile Applications

Cooling water is a crucial factor in numerous industrial applications:

  • Laser processing: Precise temperature control for optics, laser sources, and other components.
  • Plastic injection molding: Effective cooling of tools to ensure consistent production results.
  • Power electronics: Temperature management for electronic components and systems.

In addition to powerful cooling water chillers, our product range also includes the HYFRA eChilly / eChilly+ mini chillers, which offer compact solutions for smaller applications.

Service

Thorough maintenance ensures that your chiller remains operational. We offer you both regular maintenance as well as an extensive inspection after longer interruptions in operation. Both measures are integrated in our service packages.

Repair

If there is a malfunction on your chiller, an experienced technician is always quickly available for you. The HYFRA Service ensures reliable troubleshooting everywhere via a worldwide network.

Contact

*Mandatory information

Information

Information for sales

Optional information :

Lineup

Bifrequent

Drag & Drop

Attach files

Attach files max. 10 MB, documents (* .docx, *. pdf, *. png, * jpg)

info@hyfra.com +49 (0) 2687 898-0